UPS-VM
Uninterruptible Power Supply
UPS-VM
Model:
2011-7-5
RELATED PRODUCTS
Battery Charger
0
Step Up & Down AC Convertor
0
Step Up & Down AC Convertor
0
Step Up & Down AC Convertor
0
Step Up & Down AC Convertor
0
Step Up & Down AC Convertor
0
Automatic Voltage Switcher
0
Automatic Voltage Switcher
0
DETAIL

Model No. 500VA/300W 650VA/390W 800VA/480W
Technology Line Interactive
INPUT Voltage Range 160V~250V AC / 90V~140V±5V AC
Nominal Voltage 220V/230V/240V/110V/120V AC
Frequency 45~65Hz
Max. Current 1.8A 2.4A 3.0A
OUTPUT Nominal Voltage 220/230/240±2%VAC
Max. Current 1.5A 2.0A 2.4A
Voltage Range
(Normal Mode)
220V/230V/240V/110V/120V AC ±10%
Voltage Range
(Battery Mode)
220V/230V/240V/110V/120V AC ±10%(Modified Sine Wave)
Frequency
(Normal Mode)
Synchronized(Sine Wave)
Frequency
(Battery Mode)
50/60Hz±0.5Hz
Waveform Modified Sine Wave
Power Factor 0.9
Efficiency >90%
Transfer Time <10ms
BATTERY &
RUNTIME
Battery Type Maintenance-free Sealed Lead-acid Battery, Leakproof
Included Battery
Modules
1*12V/7.0Ah 1*12V/7.2Ah 1*12V/9.0Ah
Runtime
(Half/Full Load)
Full Load
3.0 minutes
Full Load
2.0 minutes
Full Load
2.0 minutes
Half Load
8 minutes
Half Load
7 minutes
Half Load
8 minutes
Discharge Time 1*(PC+17"Mon)
>=2minutes
2*(PC+17"Mon)
>=2minutes
2*(PC+17"Mon)
>=4minutes
Charge Time ≤12 Hours,Charging Up to 90%
Display Status LCD/VFD (Normal,Fault,Battery,Charge,Overload)
Audible
Alarm
Buzzer AC Normal / Battery Mode / Battery Level / Fault
Battery Mode Beeping sound every 4 seconds
after utility power fails.
Beeping sound every second
if battery approaches final discharge
Interface
Port(s)
Port Rs-232 / USB
Control Software Monitor of Utility Fault,Power Failure,
Battery,UPS Statu Indicator etc.
Software Function 1.Anlysis of Power Status, 2.Timing Controlling, 3.Monitor UPS,
4.Execute UPS Self-diagnosis, 5.Automatic Save
Cold-start Capability Yes
Protection Surge Protection &
Filtering
High Voltage,Low Voltage,Surge,Spike
Overload 
Protection
110%~130% Automatic Cut Off Output,
Buzzer Beeping(Battery Mode)
Battery Low
Voltage Protection
10V±0.2V Automatic 
Cut Off Output
Output Short
Circuit Protection
Automatic Cut Off Output,Buzzer Beeping
EMI Filter Yes
Tel/Fax/Modem Jack Yes
Regulatory Approvals CE
Operating
Conditions
Operating
Temperature
0℃~40℃
Storage
Temperature
-15℃~45℃
Relative Humidity 10%RH~95%RH,Non-condensing

FEEDBACK
Vmark International Limited
Add : 1/F., No.17, Hing Keng Shek Sai Kung,Kowloon,HongKong
Tel : 852-8226 8356
Fax : 852-8226 8357